NC2+236206+Primary Contactor Specification

  • Surface Finish
  • Matte
  • Mounting Type
  • DIN Rail / Panel Mount
  • Connector Type
  • Screw Clamp
  • Operating Temperature
  • -5°C to +40°C
  • IP Rating
  • IP20
  • Insulation Material
  • Thermoplastic
  • Power Factor
  • ≥0.85
  • Shape
  • Rectangular
  • Efficiency
  • High (Designed for continuous operation)
  • Feature
  • Arc Quenching, High Breaking Capacity, Long Mechanical Life
  • Humidity %
  • Up to 95% RH (non-condensing)
  • Overheating Protection
  • Available (with optional auxiliary relay)
  • Product Type
  • Primary Contactor
  • Application
  • Industrial Electrical Panels, Motor Starters, Control Circuits
  • Protection Level
  • IP20
  • Frequency (MHz)
  • 50/60 Hz
  • Rated Voltage
  • 690V AC
  • Energy Consumption
  • Low Power Consumption
  • Output Type
  • Auxiliary Contacts Available
  • Color
  • Grey & Black
  • Dimension (L*W*H)
  • 165 mm x 105 mm x 155 mm
  • Weight
  • 3.5 kg
  • Input Voltage
  • 230V AC/ 110V AC coil options
  • Phase
  • Three Phase
  • Size
  • Standard Compact
  • Connection Type
  • Screw Terminal
  • No Of Poles
  • 3 Pole
  • Material
  • High-grade Flame Retardant Plastic & Copper
  • Standards Compliance
  • IEC 60947-4-1, CE Certified
  • Mechanical Life
  • Over 10 Million Operations
  • Contact Material
  • Silver Alloy
  • Electrical Life
  • Over 500,000 Operations at Rated Load
  • Operating Altitude
  • Up to 2000 meters above sea level
  • Shock & Vibration
  • Tested as per IEC Standards
  • Coil Voltage Options
  • 24V, 48V, 110V, 230V AC/DC
  • Terminal Capacity
  • Upto 50 mm² Cable
  • Auxiliary Contacts
  • 1NO + 1NC (optional up to 4 contacts)
  • Short Circuit Withstand
  • 10 kA for 1 sec
 
 

About NC2+236206+Primary Contactor



Experience noteworthy performance and virtue in control with the NC2+236206+Primary Contactor, built for industrial connoisseurs. Boasting a lavish 10 million mechanical operations and crafted in premium flame-retardant plastic and copper, this 3-pole contactor guarantees lasting efficiency. Shop now to enjoy savings on this limited-time offer! Efficient arc quenching, low energy consumption, and high breaking capacity ensure safe and robust operation. Suited for diverse voltages from 24V to 230V AC/DC, it conforms to IEC and CE standards-ideal for control panels and motor starters alike.

Applications & Features: Mastery in Machine and Plant Automation

Cherished by virtuoso engineers, the NC2+236206+Primary Contactor rises to prominence in advanced machines and plant automation. Specifically designed for use in heavy-duty industrial electrical panels, motor starters, and sophisticated control circuits, it offers high breaking capacity and arc quenching. Auxiliary contacts enable seamless integration with extended systems, safeguarding operations with IP20 protection and enduring over 10 million mechanical cycles. It's a premier choice for factories and process plants requiring unwavering reliability.


Market Value & Supply: Proposals, Exports, and Sample Availability

The NC2+236206+Primary Contactor commands remarkable market value in India's domestic and export sectors. Traders and suppliers benefit from substantial proposal amounts, tailored to diverse project scales. With ready samples available, stakeholders can swiftly assess product superiority. High supply ability ensures prompt delivery to meet evolving demands. Esteemed in export markets, it empowers global clients with recognized standards, supporting both large and bespoke orders.


FAQ's of NC2+236206+Primary Contactor:


Q: How is the NC2+236206+Primary Contactor typically used in industrial settings?

A: It is primarily used in industrial electrical panels, motor starters, and control circuits to control and protect motors and large loads, offering prolonged mechanical and electrical life for continuous operations.

Q: What are the standout features that make this contactor noteworthy?

A: Notable features include silver alloy contacts, a lavish 10 million mechanical operation life, high breaking capacity, reliable arc quenching, and compatibility with various coil voltages. Its flame-retardant body and IP20 protection ensure safe use in demanding environments.

Q: When should auxiliary contacts be considered for this contactor?

A: Auxiliary contacts are ideal when integration with additional control or status circuits is needed. They can optionally expand from 1NO+1NC up to 4 contacts, enhancing flexibility in automation and monitoring.

Q: Where can I mount the NC2+236206+Primary Contactor?

A: It offers versatile mounting options, including DIN rail and panel mounting, making it adaptable to different industrial setups and control cabinet designs.

Q: What benefit does the robust short circuit withstand capability provide?

A: With a short circuit withstand of 10kA for 1 second, it enhances safety and reduces downtime by protecting equipment during fault conditions, ensuring longevity and consistent plant operation.

Tell us about your requirement
product

Price:  

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in NC2 Contactor Category

NC2 236157 Primary Contactor

NC2 236157 Primary Contactor

Protection Level : Other, High

Mounting Type : DIN Rail/Panel Mount

Output Type : Contact Output

Connector Type : Screw Connector

Rated Voltage : 690V AC

Dimension (L*W*H) : 140 mm x 86 mm x 125 mm

NC2+236307+Primary Contactor

NC2+236307+Primary Contactor

Protection Level : Other, High

Mounting Type : DIN Rail / Panel Mount

Output Type : Auxiliary Output

Connector Type : Screw Connector

Rated Voltage : 690 V AC

Dimension (L*W*H) : 150 mm × 90 mm × 125 mm

NC2+236562+Primary Contactor

NC2+236562+Primary Contactor

Protection Level : Other, IP20

Mounting Type : DIN Rail / Panel Mounting

Output Type : Contact Output

Connector Type : Screw

Rated Voltage : 690V AC

Dimension (L*W*H) : 105 x 88 x 125 mm

NC2+236970+Primary Contactor

NC2+236970+Primary Contactor

Protection Level : Other, IP20

Mounting Type : DIN Rail/Panel Mount

Output Type : Switching

Connector Type : Screw Clamp

Rated Voltage : 690 V AC

Dimension (L*W*H) : 105 mm x 85 mm x 62 mm